UNI-TECH SALES - Manufacturer of Laboratory Instruments
UNI Tech SalesUNI Tech SalesUNI Tech Sales
+91-98110 59204
info@uni-techsalesindia.com
New Delhi-110005
UNI Tech SalesUNI Tech SalesUNI Tech Sales

Bio Safety Cabinet

Bio-Safety cabinets are for international quality and are considered top-of the line by its very large number at regular users. A few unique features of these cabinets are as follows.

Safety   UV Light in work chamber inter locked with Door & Fluorescent light switches on only when door is closed and automatically switches OFF fluorescent Lights 30 Minutes auto off timer is optional

2-Stage Exhaust Protection

HEPA filters

UV Burn out with in work chamber to working Sliding Sas-Counter Balanced Door up & Down Spillage Drain System:- Collections Cannels with Drain outlet provided under the work table Front Arm Rest is provided to prevent operator’s arms from the blocking air flow and for user comfort along with Foot Rest.

Electrical

All Electrical fittings are as per 1.S.I Standard All switches are placed on the front facia of the chamber all internal wiring are protected with heat resident material, Mains are through M.C.B for higher Protection against shock /Damage. Sloped Front Ergonomically design ensures better operator comfort and more reach intro the work area. work zone made of Stainless Steel 304 Grade, Factor-Pro Installed for instant commissioning only ducting needs to be connected at side.

Optional

Virus burn unit at exhaust UV hour meter, to keep track of total UV used time, Exhaust system for ducting length above 5 feet Full body chamber work table of heavy SS 304 Grade 20 Gauge /E.G.P.C 20 Gauge

These Cabinets are available in the following Classes Varieties:

Type

Airflow Pattern Personal Product & Environmental Protection

 

Class I       

Front suction exhaust Through HEPA Filter

Personal Product & Environmental Protection

Class II Type A

70% re-circulated through

HEPA 30% Exhaust through HEPA W/O Duct

Personal & Environmental Protection

Class II

Type B

100% re-circulated through

HEPA

Personal & Environmental Protection

Class II

Type BI

30% re-circulated Through HEPA

70% Exhaust Through HEPA & Ducted

Personal & Environmental Protection

Class II

Type B2

No Re-Circulated 100%

Exhaust w/o HEPA through Ducted

YES

Specification

Specification: Laminar Air Flow Velocity: Average of 0.45m/s. Or 90 fpm measured 150mm/6″ filter face 45 Air Charges/Minute work Zone RE-CIRCULATION -70% OF TOTAL Air Velocity

Specification

With standard HEPA Filter (Minipleat HEPA Optional)

HEPA filters-     rated for min 99 97% efficiency at 0.3 micron particle Size

Pre-filters:         Low pressure drop. High efficiency 10 microns

Illumination:      By Fluorescent tube, Size as per working Area

Light intensity:   The intensity of the light at the work surface in between 800 to 1000lux

UV Sterilization:  in work chamber 7 Exhaust plenum. Emission in the germicidal band UV-Size as per      working area

Noise Level:        58 db at operator point

inter lock            UV/Flourscent liters /Doors (Optional)

Exhaust:-            Double Protection with HEPA & Hitter

Motor/Blowers: Double Shaft, Balanced, Low vibration

Power-                 220/240V AC /50 Hz 1 Phase

Dimension of work chamberSS ChamberMS Chamber
3’x2’x2′3’x2’x2′3’x2’x2′
4’x2’x2′4’x2’x2′4’x2’x2′

Other size can be designed as per customer specification on request

[elementor-template id="20"]