Feature :
- Refrigerated & Humidity Condition For Seed
- Better Mineral Puf Insulated To Keep The Surface Temp. Of Body Comfortable & avoid cooling loss
- Silent energy saving Kirloskar Compressor designed to circulate uniform Air Throughout the chamber with better imported coil condenser / copper coil improved Temperature distribution
- Polish 304 grade S. Steel interior corrosion resistant long life operation having adjustable shelves to make more space for different height.
- Kanthal A-1 tubular heater is fitted with for better accuracy
- Tubular type Kanthal A-1 Immersion heater are fitted at the bottom of tank for humidity purpose
- Windowed Front glass door, Also outer MS powder Coated door & inner full view Acrylic door to observe the Test process inside the seed Germinator as desired while keep Temp. Of Humidity
- un-interrupted Full feature Digital Temp. Controller Cum Indicator with Voltmeter
- Optional: Digital Humidity Controller. 2. Digital Voltmeter
- Angle Iron frame with castor wheel for easy movement.
- 2 Side extra door with exterior lighting arrangement (06 Nos. Fluorescent Tube Lights) with Copper choke & Starter.
- 24 Hrs. Cyclic Timer to control the illumination i.c. 6 Tube lights. Humidistate to control Humidity (On customer request)
- Safety Controller are provide with the Digital Temp Controller. Fitted with 2 Nos. Fan (one for heating & one for cooling)
Applications :
Useful for conducting various experiment on variety of seeds. Can be use as incubator.
Specification:
| Models | UTS 1.11 | UTS 1.11A |
| Capacity (Litre) | 308 Litres | 616 Litres |
| Interior (mm) | 555 x 910 x 605 mm | 555 x 910 x 605 mm (2 different Chambers) |
| Heater “W” Wattage | 500W | 500W x 2 |
| Humidity Heater Wattage “W” | 1.5KW | 1.5KW x 2 |
| Shelves | 6 Nos. & 14 Nos. | 6 Nos. & 14 Nos. |
Technical Parameters
Control Panel : Voltmeter, Mains, Humidity Indicator, (illumination L. & R), 24 Hrs. Timer
& Digital Temp. Controller
Power Consumption : 220/230V AC Supply ±10% 50HZ single Phase
Housing Material : Temp. Overshoot/Failure Control.
Temperature Range : 10°C-50°C working Range up to 40°C
Humidity Range : 50-95%+3% (in case of Digital/PID Controlled) otherwise direct.
Humidity Control : By Humidistate/Digital (Optional) otherwise direct
Refrigerant : R134 (Envoirment Friendly)
Compressor : Heavy duty Kirloskar
Interior : S. Steel 304 grade with glass window for illumination
Optional : Voltage Stablizer (Don’t use without stablizer)
RS-232/Touch Screen PLC Controller DON’T USE THE EQPT. WITHOUT WATER